[Special chiller for food use] food edible oil and oil production special cooling BBP industrial box package chiller

BBP box-type of industrial water chiller
Box-type industrial chiller product technology features:
1.Principle and Use 
Box-type industrial chillers are use air or water for condenser cooling medium , use water as the refrigerant of the industrial cooling equipment.it Widely used in various fields of plastics, electronics , food , pharmaceutical , electroplating , chemical , printing , coating , laser and CD-ROMs and other industrial equipment or mold cooling
2.Type
Within the box-type industrial chillers containing chilled water pump and water tank , on-site installation is simple , easy to maintain ; box-type industrial chillers are air-cooled and water-cooled two for the selection of customers according to the situation,.Air - cooled conditions chillers do not require cooling water system can be installed outdoors , easy to install, do not take up room space ; high water-cooled conditions chiller efficiency , wider operating temperature range .
3.Evaporator 
3 - 5HP chiller using a submerged coil evaporator unit 8HP more than a shell and tube or plate evaporator heat transfer efficiency, and water resistance .
4.Controller 
All microcomputer controller accurate , intelligent , and truly achieve perfect control of the machine , thus ensuring the safe operation of the unit and achieve the purpose of effective energy-saving , easy to use , friendly interface .
5.Water temperature & Antifreeze solution
Box-type industrial chillers can achieve a variety of cold bottled water and add the appropriate antifreeze in the chilled water side , 0C to - 15C the water temperature, in order to adapt to different industrial cooling requirements ; commonly used in antifreeze solution ethylene alcohol, sodium chloride and calcium chloride solution , proposed in the application to set different concentration of antifreeze solution to customers based on water temperature , the freezing point of a variety of solutions , please refer to the installation, use profile "section of content
6.protection  
Box-type industrial chillers have perfect protection function,such as power wrong phase lack protection , System high-voltage protection, System low voltage protection, Double antifreeze protection, Compressor overload protection, The insufficient frozen water cooling protection, Prevent frequent start protection, Compressor built-in exhaust temperature and coil overheat temperature protection and so on. Reduce losses caused by all kinds of accidents happen.
7.Receive customized
The company accept all kinds of special technical requirements of units to order, can be customized explosion-proof, strong acid, strong alkali solution, cryogenic, heterogeneous power supply, T3 conditions non-standard products before ordering please contact with our technology department. 
8.Pump & Water tank 
Containing stainless steel water pump and water tank inside the box chillers standard accessories ; Pump is lift , flow , adapt to the strong ; Large capacity water tank , can automatic replenishment , overflow , effectively buffer the load change , the introduction of water temperature fluctuations , and to stabilize the cooling system is running .
9.Microcomputer function 
Many of the chiller with compression, microcomputer automatic memory will be per compressor operation time, start the next time it will be activated running less time compressor. Similar in the discharge of the need, but also will be preferential the operation longer time to uninstall chiller, in order to achieve the balance of each compressor operation, extend the service life of the machine.
10.Environmental protection refrigerants 
Air cooled low temperature condition (10 C below) water chillers the Copeland of the low temperature and environmental protection compressor for R404A refrigerants, higher efficiency, to live longer, environmental protection and energy saving. 
In order to better protect the atmosphere, it Can producte green environmental protection etc cooling medium refrigeration and air conditioning equipment not only in adopts HFC407C and HFC134a,but also in HCFC22.
11.Movement
3- 8HP of the box-type industrial chiller`s bottom of the fuselage is equipped with a wheel, you can easily move .

12.Compressor & major refrigeration original

Compressor selection of Europe and the United States imports closed scroll compressor (Or  piston ) , small vibration, resistance to liquid strike capability , high efficiency , wide operating temperature range.
    In addition to the compressor refrigeration components are imported quality products, such as the expansion valve , solenoid valve , filter drier , etc. European and American quality products , reliable performance and precise control .
13.Test center 

The enterprise has a well-operated testing center , each air-conditioning unit have been injected refrigerant and refrigerant oil before leaving factory. After undergoing a rigorous simulation of the standard conditions and maximum operating mode detection, expansion valve can be adjusted to the best condition.


Model Explanation


BB

P

40

D

W

b

E

   

 

 

  ①    B.BUSCH Series of Chillers

         ②    Type of Logo: BBP--- Packaged industrial chiller

         ③    The compressor output power (HP)

         ④    The number of compressor:  S---Single compressor

                                                      D---Double compressors

         ⑤    Heat source description: W---Water cooled

                                           A--- Air cooled

  ⑥ Working temperature: a--- -5 deg.C water condition

                                          b--- -15 deg.C water condition

   --- omitted for Normal conditioning 7 deg.C water

         ⑦  Special signs of Packaged industrial chiller: E----Not include the water pump and water tank

                                                                  P----only water Pump internal,not water tank

                                                                          --- omitted for include the water pump and water tank


Notes: (room temperature) default conditions 

1.The parameters in the nominal conditions are as follows: chilled water inlet / outlet water temperature is 12℃/ 7 ℃; Ambient temperature is 35℃ . 
2. Temperature conditions: Chilled water inlet temperature range 9℃ ~ 20 ℃ ambient operating temperature 0 ° C ~ 43 ℃
3. Host the actual head of the pump head , minus the host internal head loss ( 1mH2O = 9.8kPa )
4. Nominal conditions evaporation device water side of the dirt coefficient is 0.018 m • ° C / kW
5. Power standard : 3P- 380V - 50HZ , it is recommended that the three-phase system , allowing the voltage fluctuation of ± 5 % , the frequency fluctuations of ± 2%


Notes: (-5℃ temperature) default conditions
1.The parameters in the nominal conditions are as follows: chilled water inlet / outlet water temperature is 0℃/ -5 ℃; Ambient temperature is 35℃. Chilled water side must add 25% ethylene glycol solution or calcium chloride solution of 15% antifreeze
2. Temperature conditions: Chilled water inlet temperature range -2℃ ~ 15 ℃ ambient operating temperature 0 ° C ~ 43 ℃
3. Host the actual head of the pump head , minus the host internal head loss ( 1mH2O = 9.8kPa )
4. Nominal conditions evaporation device water side of the dirt coefficient is 0.018 m • ° C / kW
5. Power standard : 3P- 380V - 50HZ , it is recommended that the three-phase system , allowing the voltage fluctuation of ± 5 % , the frequency fluctuations of ± 2%

Notes: (-15℃ temperature) default conditions
1.The parameters in the nominal conditions are as follows: chilled water inlet / outlet water temperature is -10℃/ -15 ℃; Ambient temperature is 35℃. Chilled water side must add 35% ethylene glycol solution or calcium chloride solution of 22% antifreeze

2. Temperature conditions: Chilled water inlet temperature range-12℃ ~ 15 ℃ ambient operating temperature 0 ° C ~ 43 ℃
3. The chiller uses a dedicated low-temperature refrigerant R404A
4. Host the actual head of the pump head , minus the host internal head loss ( 1mH2O = 9.8kPa )
5. Nominal conditions evaporation device water side of the dirt coefficient is 0.018 m • ° C / kW
6. Power standard : 3P- 380V - 50HZ , it is recommended that the three-phase system , allowing the voltage fluctuation of ± 5 % , the frequency fluctuations of ± 2%